• Power industry, 0.5-40kVA
    Basic Features

    Product characteristics

     The inverter power supply (also called the inverter) uses the SPWM and the CPU control technology, and the main circuit uses the imported power module.12V / 24V / 48V / 110V / 220V DC power supply into 220V, 50Hz voltage stabilization, frequency stabilization, low noise, pure sine wave AC power supply.

    With the rapid development of information network technology, sine wave inverter power as a new generation of DC / AC conversion power has been widely used in telecommunications, mobile, Unicom, aerospace, railway, financial management, office automation, industrial automatic control, medical and health, military research and other fields. Sine wave inverter power using battery dc as an input, after the inverter output pure sine wave ac, output voltage and frequency and is very stable and work continuously for a long time, eliminate the direct use of mains power supply interruption, voltage instability, noise interference and lightning intrusion adverse factors, at the same time overcome the small UPS power supply time short defects, to ensure continuous and reliable electrical equipment. Equipped with sine-wave inverter power supply is the best guarantee for the safe and reliable operation of the system.

    product model

    Power industry inverter power supply

    High frequency (ND Series)

    DC 220V input AC 220V output

    DC 110V input AC 220V output

    Power frequency (NB series)

    DC 220V input AC 220V output

    DC 110V input AC 220V output

    Communication industry inverter power   supply

    High frequency (ND Series)

    DC 48V input to AC 220V output

    Power frequency (NB series)

    DC 48V input to AC 220V output


     Application place
    The inverter power supply designed for the post and telecommunications industry is suitable for program-controlled switches, computer room, network, billing server and lighting places with 48V (or-48V) DC power (DC screen).
     The inverter power supply designed for the power industry, input DC voltage is 110V / 220VDC, output is 220VAC / 50Hz pure sine wave AC power supply, mainly used in power plants, power system, railway and other important places.
     The main characteristics of the high-frequency inverter power supply
     Compound protection mode of software protection and hardware protection, with high reliability.
     With perfect protection functions: input polarity reverse connection, input overvoltage, output overvoltage, overcurrent, short circuit, overheating in the machine, and other soft start function.
     Using three composite filter and magnetic shielding, to reduce the noise voltage of the input, excellent electromagnetic compatibility.
     Intelligent fan speed control system.
     Can be connected to pure perceptual load (to reduced use).
     Small volume, light weight, high efficiency, simple operation, no pollution.
     Main characteristics of power frequency inverter power supply

     Power frequency inverter power supply is a new type of inverter power supply designed by using advanced high frequency pulse width modulation technology and microcomputer control technology. It has the advantages of high reliability, full protection function and small waveform distortion.

    It is a 220V DC into AC 220V / 50Hz, voltage stabilization, frequency stabilization, low noise. The product has a high conversion efficiency (up to 80% under full load state). There is also a strong non-linear load driving capacity. This series of inverter power supply can also monitor the input voltage, current and output voltage, current, so as to realize unattended.

    ◆ Adopt advanced SPWM and CPU control technology;

    ◆ High reliability, input and output isolation, safety and efficiency, small waveform distortion and other advantages;

    ◆ With the perfect protection function:
    1. Output overload protection; input reverse connection protection;
    2. Output overvoltage protection; input lowvoltage protection;
    3. Output short-circuit protection; input overvoltage protection;

    ◆ Automatic bypass and uninterrupted conversion, to achieve the continuous work of the equipment.

    ◆ Can be used in a relatively harsh environment, with strong stability and high reliability.

    ◆ Has a strong nonlinear load drive capacity, can make high-power power supply.

     

    Technical Specifications

    technical specifications
    (I) High-frequency inverter power supply for electric power (ND series): DC 220V input AC 220V input output

    model

    ND500

    ND1000

    ND2000

    ND3000

    ND4000

    ND5000

    ND6000

    rated   capacity

    500VA

    1000VA

    2000VA

    3000VA

    4000VA

    5000VA

    6000VA

    output   rating

    400W

    800W

    1600W

    2400W

    3200W

    3500W

    4200W

    DC   input

    Rated   input voltage

    220V

    Rated   input current

    3A

    5A

    10.5A

    16A

    21A

    26.3A

    31.6A

    Turn   off the voltage range

    190V270V

    Boot   voltage range

    207V260V

    Reverse   perfusion noise current

    ≤10%

    AC   input

    Permit   bypass voltage

    220Vac±15%

    Rated   input current

    2.3A

    4.5A

    9.1A

    13.6A

    18.2A

    22.7A

    27.3A

    Bypass   conversion time

    ≤5ms

    AC   output

    Rated   output voltage and frequency

    220Vac,50Hz

    wave   form

    pure   sine wave

    rated   output current

    1.8A

    3.6A

    7.2A

    10.8A

    14.5A

    15.9A

    19.1A

    Output   voltage accuracy

    220V±1.5%

    Output   frequency accuracy

    50Hz±0.1%

    waveform   distortion rate (THD)

    3%   (Linear load)

    Dynamic   response time

    5%   (load of 0100%)

    power   factor (PF)

    0.7/0.8

    overload   capacity

    120%,   30s

    inversion   efficiency

    ≥85%

    Working   environment

    insulation   strength

    1,500   Vac, 1 min

    Noise   (1 m)

    ≤40dB

     ambient temperature

    -5℃40℃

    humidity

    0~90%,   with no condensation

    altitude

    ≤1000m

    cooling-down   method

    air   blast cooling

    Inverter   status

    Municipal   s is normal, inverter is normal, battery low voltage, output overload

    Mechanical   size

    19-inch   rack-type (2U) mm

    482×88.8×252

    482×88.8×352

    482×88.8×382

    483×176×414

    weight

    5Kg

    7Kg

    8Kg

    11Kg

    12Kg

    13Kg

    14Kg

    Desktop   (width and depth)

    /

    175×274×452(mm)

    220×330×452(mm)

    weight

    /

    8Kg

    9Kg

    12Kg

    13Kg

    15Kg

    16Kg

    color

    Computer   is white (grey) \ black

    protection   function

    Input   low voltage and overvoltage; output overload, short circuit protection, mains   high and low voltage protection

    Output   method

    Socket   outlets or wiring terminals

    Wiring   terminals


    (2) High-frequency inverter power supply for electric power (ND series): DC 110V input AC 220V output

    model

    ND500

    ND1000

    ND2000

    ND3000

    ND4000

    ND-HD5000

    ND6000

    rated capacity

    500VA

    1000VA

    2000VA

    3000VA

    4000VA

    5000VA

    6000VA

    output rating

    400W

    800W

    1600W

    2400W

    3200W

    3500W

    4200W

    DC input

    Rated input voltage

    110V

    Rated input current

    6A

    11A

    22A

    33.3A

    44.4A

    55.6A

    66.7A

    Turn off the voltage range

    94V132V

    Boot voltage range

    101V127V

    Reverse perfusion noise current

    ≤10%

    AC input

    Permit bypass voltage

    220Vac±15%

    Rated input current

    2.3A

    4.5A

    9.1A

    13.6A

    18.2A

    22.7A

    27.3A

    Bypass conversion time

    ≤5ms

    AC output

    Rated output voltage and frequency

    220Vac,50Hz

    wave form

    pure sine wave

    rated output current

    1.8A

    3.6A

    7.2A

    10.8A

    14.5A

    15.9A

    19.1A

    Output voltage accuracy

    220V±1.5%

    Output frequency accuracy

    50Hz±0.1%

    waveform distortion rate (THD)

    3% (Linear load)

    Dynamic response time

    5% (load of 0100%)

    power factor (PF)

    0.7/0.8

    overload capacity

    120%, 30s

    inversion efficiency

    ≥85%

    Working environment

    insulation strength

    1,500 Vac, 1 min

    Noise (1 m)

    ≤40dB

    ambient temperature

    -5℃40℃

    humidity

    0~90%, with no condensation

     altitude

    ≤1000m

    cooling-down method

    air blast cooling

    Inverter status

    Municipal s is normal, inverter is   normal, battery lowvoltage, output overload

    Mechanical size

    19-inch rack-type (2U) mm

    482×88.8×252

    482×88.8×352

    482×88.8×382

    483×176×414

    weight

    5Kg

    7Kg

    8Kg

    11Kg

    12Kg

    13Kg

    14Kg

    Desktop (width and depth)

    /

    175×274×452(mm)

    220×330×452(mm)

    weight

    /

    8Kg

    9Kg

    12Kg

    13Kg

    15Kg

    16Kg

    color

    Computer is white (grey) / black

    protection function

    Input lowvoltage and overvoltage; output   overload, short circuit protection, mains high and low voltage protection

    Output method

    Socket outlets or wiring terminals

    Wiring terminals


    (3) Power frequency inverter power supply for power (NB series): DC 220V DC input, AC 220V output

    model

    NB1K

    NB2K

    NB3K

    NB4K

    NB5K

    NB6K

    NB10K

    NB15K

    NB20K

    NB25K

    NB30K

    NB40K

    Bypass and DC input

    specified
      capacity

    1KVA

    2KVA

    3KVA

    4KVA

    5KVA

    6KVA

    10KVA

    15KVA

    20KVA

    25KVA

    30KVA

    40KVA

    Bypass the rated input voltage

    220Vac±20%50Hz±10%

    DC input voltage

    220Vdc

    Rated input current

    4.5A

    8.5A

    13A

    17.5A

    21.5A

    26A

    43A

    64.5A

    86A

    107A

    128.5A

    182A

    DC input startup voltage

    190Vdc300Vdc

    DC input off-off voltage

    180Vdc300Vdc

    Communication output

    output power

    0.8KW

    1.6KW

    2.4KW

    3.2KW

    4.0KW

    4.8KW

    8.0KW

    12KW

    16KW

    20KW

    24KW

    32KW

    Output voltage and frequency

    220 Vac ± 20% (municipal mains status);   220 Vac ± 2% (inverter state); 50Hz ± 1%

    rated output current

    4A

    7A

    11A

    15A

    18A

    22A

    36A

    55A

    73A

    91A

    109A

    145A

    power factor

    0.8 lag

    discharge waveform

    pure sine wave

    total harmonic distortion

    ≤3%

    Dynamic load voltage transient

    ± 5% (load 0~100% transition)

    overload capacity

    (125~150%) automatically transfer to   bypass after 30 seconds, restored after normal load;> 150%, 200ms   transferred to bypass and not recoverable

    full load efficiency

    99% (mains state); 85% (inverter state)

    Bypass conversion time

    ≤6ms

    protection function

    Overload, battery with low voltage, lowvoltage,   overvoltage, and system failure

    display mode

    The pointer header is displayed

    work environment

    insulation strength

    Input / output to ground 1500VAC, 1 min,   leakage current<3.5 mA

    cooling-down method

    air blast cooling

    noise

    55dB

    ambient temperature

    -10℃40℃

    relative humidity

    0~95% with no condensation

    Use the altitude

    1500m

    Mechanical size

    Rack type (width and depth) mm

    482×133×450

    482×177×450

    482×221.5×500

    /

    /

    /

    /

    /

    /

    weight

    28KG

    36KG

    45KG

    50KG

    55KG

    58KG

    /

    /

    /

    /

    /

    /

    Desktop (width and depth) mm

    210×540×612

    240×680×540

    330×885×640

    500×1200×680

    380×935×680

    500×1200×680

    700×1600×853

    weight

    26KG

    36KG

    46KG

    50KG

    57KG

    60KG

    145KG

    145KG

    200KG

    200KG

    270KG

    300KG


    (4) Power frequency inverter power supply (NB series): DC 110V input AC 220V output

    model

    NB1K

    NB2K

    NB3K

    NB4K

    NB5K

    NB6K

    NB10K

    NB15K

    NB20K

    Bypass and DC input

    rated capacity

    1KVA

    2KVA

    3KVA

    4KVA

    5KVA

    6KVA

    10KVA

    15KVA

    20KVA

    Bypass the rated input voltage

    220Vac±20%50Hz±10%

    DC input voltage

    110Vdc

    Rated input current

    9A

    17A

    26A

    34A

    43A

    51A

    86A

    128A

    171A

    DC input startup voltage

    95Vdc150Vdc

    DC input off-off voltage

    90Vdc150Vdc

    Communication output

    output power

    0.8KW

    1.6KW

    2.4KW

    3.2KW

    4.0KW

    4.8KW

    8.0KW

    12KW

    16KW

    Output voltage and frequency

    220 Vac ± 20% (municipal mains status);   220 Vac ± 2% (inverter state); 50Hz ± 1%

    rated output current

    4A

    7A

    11A

    15A

    18A

    22A

    36A

    55A

    73A

    power factor

    0.8 lag

    discharge waveform

    pure sine wave

    total harmonic distortion

    ≤3%

    Dynamic load voltage transient

    ± 5% (load 0~100% transition)

    overload capacity

    (125%~150%) automatically transfer to   bypass after 30 seconds, recover after normal load;> 150%, 200ms to   bypass, not recoverable

    full load efficiency

    99% (mains state); 85% (inverter state)

    Bypass conversion time

    ≤6ms

    defencive function

    Overload, battery low voltage, lowvoltage,   overvoltage, and system failure

    display mode

    The pointer header is displayed

    work environment

    insulation strength

    Input / output to ground 1500VAC, 1 min,   leakage current<3.5 mA

    cooling-down method

    air blast cooling

    noise

    55dB

    ambient temperature

    -10℃40℃

    relative humidity

    0~95% with no condensation

    Use the altitude

    1500m

    Mechanical size

    Rack type (width and depth) mm

    482×133×450

    482×177×450

    /

    weight

    28KG

    36KG

    45KG

    /

    /

    /

    /

    /

     

    Desktop (width and depth) mm

    200×490×480

    210×540×612

    240×680×540

    330×885×640

    500×1200×680

    weight

    26KG

    36KG

    46KG

    50KG

    55KG

    58KG

    120KG

    145KG

    200KG

本站部分图文来源网络,如有侵权问题请通知我们处理!