• power frequency online UPS 10 ~ 500kVA
    Basic Features

    ● Double conversion true online design, using digital technology UPS with perfect protection function and high reliability;

    1.The inverter adopts the full digital vector control technology of dual DSP, MCU and DDC real-time processing, to accurately control the parameters of the machine and conduct comprehensive control over it.

    2.Advanced IGBT high-frequency pulse width modulation technology (PWM) is combined to reduce system noise and power loss, and ensure that customers can obtain high quality voltage output and the highest benefit in various working load states.

    3.Double conversion, pure online sine wave output, no matter in the mains mode or battery mode, can output low distortion pure sine wave power supply, to provide the best power supply guarantee for the user's load equipment.

    4.Output belt isolation transformer to ensure the full isolation of load and public power grid. The machine equipped with isolation transformer will not appear DC components in the load, can effectively protect the computer, the switching power supply of network and communication equipment is not damaged by DC current, at the same time, for the nonlinear load, can also show excellent dynamic performance, improve the load capacity of the machine, and the load compatibility is good.

    5.Automatic frequency / phase synchronization function to avoid the impact of input frequency hopping on the device.

    6.Perfect protection function, with AC input overvoltage, low voltage protection, output overvoltage low voltage protection, output overload short circuit protection, battery low voltage warning protection, overtemperature protection, so as to greatly ensure the stability and reliability of the system operation.

    7.The use of high-power IGBT devices makes the inverter have a strong overload capacity and impact resistance, and enhances the adaptability to the power grid.

    8.Intelligent speed regulating fan, low noise and energy saving

    9.Chinese and English LCD operation interface, more convenient management.

    ● Flexible parallel machine technology is suitable for different loads of the system single machine, 1+1 parallel machine, N+1 parallel machine operation;

    Make the parallel UPS in a relatively independent working state, intelligently, quickly and accurately to the best (phase difference<0.50), dynamic implementation of the load active and reactive power, and realize the precise load evenly, from the fault UPS system accurately and reliably, ensure that the parallel system continues to provide high quality ac power supply, the parallel system UPS circulation is almost zero, the current imbalance is less than 2%.

    Multi-machine parallel system: allows users to realize parallel operation of up to eight UPS in key applications. Advanced monitoring and high DSP digital control technology make the parallel system as simple as single machine. All UPS are equal, and there is no master-slave relationship, which is real equality. If you buy a single such UPS, you can easily expand to a "1 + 1" dual parallel machine when you need to expand or improve your reliability, or continue to expand to an N + X multi-machine redundancy system.

    ● The parallel machine can share the battery pack

    Greatly convenient for users to use, and for users to save costs.

    ● Intelligent battery management mode

    The intelligent battery charge and discharge mode and management mode can effectively improve the battery life, and matching the corresponding components can accurately calculate the battery discharge time, convenient for user management.

    ● The system has undergone strict short circuit test and 2KV high voltage insulation test;

    ● Full digital control technology, so that the whole machine control is accurate, fast, reliable and stable;

    ● Twelve pulses or active filter to effectively correct the input power factor and prevent the UPS to pollute the power grid;

    ● Powerful intelligent monitoring function, can provide RS232, RS485, dry contact point and parallel machine interface;

    UPS power supply environment monitoring system, with the international leading technology level, has developed intelligent single and network integration real-time monitoring management software, providing users with professional, perfect, practical, safe and reliable power monitoring scheme, so that intelligent network quickly and reliably manage UPS system. UPS centralized monitoring and management software can monitor UPS worldwide, integrating point-to-point to-point, point-to-many, multi-to-point, many-to-many full-function network topology structure, forming a huge intelligent UPS power network monitoring and management system.

    Features of the real-time monitoring software:

    1. Real-time monitoring for single users;

    2. Real-time monitoring for the centralized management of large-scale WAN.

    ● Flexible networking scheme

    RS232, RS485, dry contact, SNMP card, Modem can meet TCP / IP protocol and adapt to LAN, WAN and INTERNET network monitoring.

    1. The RS232 serial communication interface is connected one to one, which is directly connected with the RS232 communication port of the computer, realizing the two-way data exchange, remote monitoring and intelligent management in close distance (<100m) between the computer and UPS equipment.

    2. RS485 adopts advanced balance circuit, improved interface RS485 serial communication standard, duplex communication mode, one-to-one connection. Dedicated RS485 / RS232 interface converter is connected to the communication interface of RS232 of the computer and connected to the computer through a cable to support data transmission at high speed and distance (<1200mm).

    3, SNMP network card adopts the world's popular Ethernet technology, advanced TCP / IP network protocol, duplex communication mode, many-to-many connection. UPS built-in or external dedicated SNMP network card connects with computer-configured network card to realize intelligent monitoring of<100m; it is also connect to the LAN to implement networked monitoring of one (or multiple) UPS.

    4. UPS built-in Modem can dial through the telephone line to the local telephone network, call the landline, mobile phone, prompt the UPS abnormal state: bypass, shutdown, battery low voltage, overload, etc.

    5. The UPS dry contact alarm signal conducts long-distance alarm through the contact closure, connects the remote indicator light, electric bell and relay execution unit, prompting no city power, battery low voltage, machine fault, etc.

     

    Technical Specifications

    (I) Rectifier input and output parameters

    1.Rectifier input parameters

    Model

    10kVA

    20kVA

    30kVA

    40kVA

    60kVA

    80kVA

    100kVA

    120kVA

    160kVA

    200kVA

    250kVA

    300kVA

    400kVA

    500kVA

    Nominal capacity (kW)

    8

    16

    24

    32

    48

    64

    80

    96

    128

    160

    200

    240

    320

    400

    Single-phase maximum input 

    current (A)

    19

    38

    57

    76

    114

    152

    190

    228

    304

    379

    475

    570

    760

    950

    Working mode and principle

    Online   power supply, static bypass switch (no intermittent switching), dual   conversion technology, the output power supply is

    completely   isolated

    Input power factor

    0.8/0.9(12 pulses)/0.95(with     active filter)

    Number of phases

    Three-phase+N+G

    Nominal voltage

    380VAC±25%

    Nominal frequency

    50/60Hz±10%

    Input current harmonics

    <5%

    Soft start

    0~100%5sec

    2.rectifier output  parameters

    Model

    10kVA

    20kVA

    30kVA

    40kVA

    60kVA

    80kVA

    100kVA

    120kVA

    160kVA

    200kVA

    250kVA

    300kVA

    400kVA

    500kVA

    Maximum output voltage (VDC)

    432V

    The microcomputer sets the 

    charging current

    6~30A(adjustable)

    (2) Battery

    Model

    10kVA

    20kVA

    30kVA

    40kVA

    60kVA

    80kVA

    100kVA

    120kVA

    160kVA

    200kVA

    250kVA

    300kVA

    400kVA

    500kVA

    Maximum discharge current (A)

    28

    56

    85

    113

    169

    225

    282

    338

    461

    576

    700

    840

    1120

    1400

    Number of batteries per group

    12V32pcs or 2V192pcs

    Nominal battery voltage

    384VDC

    Floating charge voltage

    432VDC

    Charging current

    6~30A(adjustable)

    (3) Inverter

    Model

    10kVA

    20kVA

    30kVA

    40kVA

    60kVA

    80kVA

    100kVA

    120kVA

    160kVA

    200kVA

    250kVA

    300kVA

    400kVA

    500kVA

    Power rating (kW)

    8

    16

    24

    32

    48

    64

    80

    96

    128

    160

    200

    240

    320

    400

    Number of phases

    Single-phase  three-phase+N+G

    three-phase+N+G

    Nominal voltage

    220/380VAC±1% (steady state)

    380VAC±1% (steady state)

    Nominal frequency

    50/60Hz±0.5% (battery mode)

    Output power factor

    0.8/0.9

    Frequency stability

    <±0.5% (when out of     synchronization)

    <±2% (when synchronized     with mains)

    Crest factor

    3:01

    Discharge waveform

    sinusoidal wave

    Total harmonic distortion

    Linear   load<3%;   nonlinear load <5%

    Dynamic load voltage transient

    <14%

    Moment recovery time

    <10ms

    Balanced load voltage

    <± 1%;<15% (unbalanced   negative hub)

    Overload capacity

    125%30min,150%1min,>150%300ms

    Inverter efficiency (load of 

    100%)

    >93%

    >96%

    (4) Bypass

    Model

    10kVA

    20kVA

    30kVA

    40kVA

    60kVA

    80kVA

    100kVA

    120kVA

    160kVA

    200kVA

    250kVA

    300kVA

    400kVA

    500kVA

    Number of phases

    Single-phase or three-phase+N+G

    Three-phase+N+G

    Nominal voltage

    380VAC±15%

    Nominal frequency

    50/60Hz±10%

    Transfer time

    0ms

    (5) System

    Model

    10kVA

    20kVA

    30kVA

    40kVA

    60kVA

    80kVA

    100kVA

    120kVA

    160kVA

    200kVA

    250kVA

    300kVA

    400kVA

    500kVA

    Computer communication 

    interface

    RS232, RS485, dry contact, smart   slot

    Running temperature

    0~40

    Relative humidity

    0%~90%  (no condensation)

    Operating height(max.)

    <1000m (1% for 100m, maximum   4000m)

    Cooling-down method

    Forced draft

    Noise

    48~65dB

    53~68dB

    MTBF

    300000 Hours

    Levels of protection

    IP20

    Box color

    Black(optional white)

    Input cord

    Bottom/back

    Easy to maintain

    Front/ top/side

    Outline dimension (mm)

    D

    685

    760

    800

    880

    1050

    W

    360

    360

    660

    900

    1550/2250(12 pulses)

    H

    825

    990

    1550

    1650

    1900

    Reference Weight (kg)

    128

    175

    230

    280

    380

    550

    650

    700

    850

    900

    1050

    1500

    1700

    1900

    Input equipment

    Terminal row

    Output equipment

    Terminal row

    Note: Customizable output power PF=0.9.

    * The above parameters may be adjusted and changed, please refer to the physical object

     