◆ Real online UPS, pure sine wave output, the application of dual conversion pure online IGBT technology, small volume, low noise, durable.
◆ LCD display panel, through the LCD selection switch, convenient to check the UPS working state: whether the battery is normal, input / output voltage value, input / output frequency value, battery voltage value, output power and other important parameters.
◆ The input voltage is particularly wide, allowing 25% of the change can be full load work, reduce the opportunity of battery discharge, effectively extend the life.
◆ The charging current is 1~10A adjustable, which meets the charging requirements of the long-time power supply system, especially designed for China's power grid.
◆ Special static switch design, with zero output interruption during power grid failure, and a bypass output time of<2 ms during UPS failure.
◆ Very strong load capacity, 125% load online work for 15 minutes, load more than 125% online work for 60 seconds to bypass, load more than 150%3 seconds to bypass output, overload phenomenon disappeared after the automatic restart operation.
◆ Output short circuit protection to ensure that the UPS is not damaged by short circuit of external load.
◆ Temperature control and protection, set the internal temperature, protection component life.
◆ Has a powerful load start function, can be directly turned on in the battery state, supply output.
◆ Input / output is completely isolated, with strong anti-interference ability, strong impact resistance, safe and reliable.
◆ Provide a dual-machine thermal backup power supply system.
◆ Unique sound alarm to remind the user to notice the working state of the UPS.
◆ Built-in maintenance bypass, can achieve online maintenance.
◆ RS232 communication interface, with optional remote monitoring function.
Model
|
DP1kVA
|
DP2kVA
|
DP3kVA
|
DP6kVA
|
DP10kVA
|
DP15kVA
|
DP20kVA
|
Capacity
|
0.8kW
|
1.6kW
|
2.4kW
|
4.8kW
|
8kW
|
12kW
|
16kW
|
Input voltage
|
220/230VAC±25%
|
Input frequency
|
50/60Hz±10%
|
Output voltage
|
220VAC±1%
|
Output frequency
|
50/60Hz±0.5% (battery mode, unlocked)
|
Voltage error
|
±2%
|
Temporal reaction
|
±4% (100% load)
|
Wave form
|
Sine wave THD<3%
|
Overload capacity
|
125% load working online for 15 minutes, load over 125% online working for 60 seconds to bypass, load over 150%3 seconds to bypass output
|
Wave peak ratio
|
3:1
|
Battery type
|
Enclosed maintenance-free lead-acid battery
|
DC voltage (extended time with external battery)
|
48VDC
|
96VDC
|
192VDC
|
Battery capacity of standard device
|
12V7AH×4
|
12V7AH×8
|
12V7AH×16
|
Charging current
|
1~10A adjustable
|
Efficiency
|
90%
|
Transfer time
|
Zero ms for mains failure and<2ms for bypass switch
|
Protection function
|
Over-current, overvoltage, low voltage, short circuit, battery overcharge, overheat protection, etc
|
EMC
|
EN62040-2:2006; EN61000-3-2:2006+A1:2009+A2:2009
|
Power loss alarm
|
1 time/4s, keep 90s
|
Battery low-voltage alarm
|
1 second/ 1 time (battery discharge to protection voltage, UPS automatically
shutdown, automatically boot when mains recovery)
|
Overload alarm
|
Continuous calling (hold the jump bypass for 60 seconds, automatic recovery
after load reduction)
|
Failure warning
|
Continuous beep
|
LED display
|
main input/ bypass/ inverter/ low battery/ overload/ fault
|
LCD display
|
UPS status: input/ output/ battery voltage, input/ output frequency, load amount
|
Communication interface
|
Rs-232/ dry contact, support remote monitoring and management
|
Running temperature
|
0℃~40℃
|
Running height
|
Elevation<1000 m (1% for every 100 m, maximum 4000 m)
|
Humidity
|
0%~90% (no condensation)
|
Noise
|
<58dB
|
Dimension (D×W×H) mm
|
520×180×400
|
595×215×420
|
590×245×530(730)
|
685×360×825
|
Reference Weight (kg)
|
Extended time
|
30
|
41
|
52
|
48
|
69
|
130
|
155
|
Standard
|
41
|
58
|
69
|
85
|
110
|
147
|
172
|
Note: Customizable output power PF=0.9.
* The above parameters may be adjusted and changed, please refer to the physical object.